ProfiLux 4 Programming Guide
EN 2017-02-06 68
8 System
8.1 Factory Settings
After selection of this function you are asked if the factory settings shall be restored: Factory
settings now? If this is accepted, all settings are reset to their delivery status! The operating
hour meters are not reset.
8.2 PIN
A personal identification number (PIN) is used to protect the device against unauthorized
changes. Factory default is set to 0000. If the PIN is set to 0000, all changes can be made
without entering a PIN. As soon as the PIN is unequal to 0000, this PIN must be entered
before each setting. This also applies to the PIN change.
8.3 Socket Outlet Function
Here, the previously adjusted functions for connected powerbars or dosing pumps of the
first generation of GHL (hardware) are here assigned to the switch sockets/outlets
(hardware).
First, select the socket to which you want to assign a function. ProfiLux 4 can control a
maximum of 64 sockets.
You can assign the following functions:
Timer
Then select the Number of the timer.
This switching output is controlled by the corresponding timer.
Dosing pump
Then select the Number of the dosing pump.
This switching output is controlled by the corresponding dosing
pump control.
TIP
If you forgot your PIN
Switch off the device (disconnect the voltage supply), switch it on again (plug
in the voltage supply again). Immediately, while the status and greetings
screen is displayed, press the left arrow.
You will be asked: Are you going to delete the PIN?
After confirmation with Yes, the PIN is reset to factory default (0000 -
deactivated).

Table of Contents

Other manuals for GHL ProfiLux 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GHL ProfiLux 4 and is the answer not in the manual?

GHL ProfiLux 4 Specifications

General IconGeneral
ModelProfiLux 4
CategoryController
Power Supply12V DC
pH Ports2
Redox Ports1
Conductivity Ports1
Level Ports4
Digital Inputs4
12V Outputs4
Real-time clockYes, with battery backup
Digital Outputs4
ExpandableYes
ConnectivityUSB, Wi-Fi, LAN
DisplayGraphic LCD display
Expansion Slots4
Processor32-bit
Channels16
Operating Temperature0°C to 50°C