ProfiLux 4 Programming Guide
EN 2017-02-06 60
5.16 Current Actual value
The current actual value is displayed here. Press any key to stop the display.
5.17 Operation Mode controller
Here you can set how the control should work.
For most cases, the default Two-position controller is perfectly adequate and does not need to
be changed. For some special conditions, the other operating modes are suitable for
optimizing the control behavior. The following operating modes are available:
Two-position controller
This is the most common mode. At two switching points, which are determined by
nominal value and hysteresis, an associated socket is switched on or off. See also
Sensor Settings-> Hysteresis.
Pulse/Pause fixed
If the actual value deviates from the nominal value by a half hysteresis, the
corresponding switch socket is switched on for an adjustable time (Pulse duration).
After the pulse has elapsed, the socket is switched off again and remains switched off
for at least the set Pause duration. After the Pause duration has elapsed, the socket can
be switched on again by the controller if the actual value deviates from the nominal
value (or still) by half a hysteresis. The switching cycle (Pulse and Pause) starts again.
Pulse variable
Operates in principle like Pulse/Pause fixed. The difference is, that the actual switch-on
time is calculated depending on the difference between nominal value and actual
value.
The bigger the deviation, the longer the turn-on time will be, but at maximum as long
as the set Pulse duration.
Pause variable
Operates in principle like Pulse/Pause fixed. The difference is, that the actual switch-off
time is calculated depending on the difference between nominal value and actual
value.
The bigger the deviation, the shorter the turn-off time will be, but at maximum as long
as the set Pause duration.
For these operation modes you need to set additionally:
Pulse duration
For this duration the corresponding socket is switched on (at the maximum). You can
set a pulse duration between 1 s and 1 h.

Table of Contents

Other manuals for GHL ProfiLux 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GHL ProfiLux 4 and is the answer not in the manual?

GHL ProfiLux 4 Specifications

General IconGeneral
ModelProfiLux 4
CategoryController
Power Supply12V DC
pH Ports2
Redox Ports1
Conductivity Ports1
Level Ports4
Digital Inputs4
12V Outputs4
Real-time clockYes, with battery backup
Digital Outputs4
ExpandableYes
ConnectivityUSB, Wi-Fi, LAN
DisplayGraphic LCD display
Expansion Slots4
Processor32-bit
Channels16
Operating Temperature0°C to 50°C