ProfiLux 4 Programming Guide
EN 2017-02-06 48
pH
0.5
3.0
0.1
Temperature
0.5 °C
5.0 °C
0.1 °C
Redox
40 mV
400 mV
1 mV
Conductivity freshwater
50 µS
500 µS
1 µS
Conductivity saltwater
2.5 mS
25.0 mS
0.1 mS
Oxygen
2.0 %
20.0 %
0.1 %
Humidity
1.0 %
20.0 %
0.1 %
Air temperature
1.0 °C
15.0 °C
0.1 °C
Voltage
0.10 V
6.00 V
0.01 V
5.6 Nocturnal Change
With this setting, you can determine whether the value to be controlled is to be changed at
night.
By default, the night change is disabled. If you have activated the nocturnal change with Yes,
you can set how much the value is to be changed at night and set the start and end times.
Overview of the settings for the nocturnal change:
Example for the calculation of the lower and
upper temperature alarm limit
Nominal value 26.0 °C
Nocturnal change by -2 °C active
Overall hysteresis 0.2 °C
Maximum devitation 1.5 °C
Cooling difference 2.0 °C
Thus resulting :
Lower limit = 26.0 °C 2.0 °C ½ * 0.2 °C 1.5 °C = 22.4 °C
Upper limit = 26.0 °C + 5/6 * 0.2 °C + 1.5 °C + 2.0 °C = 27.7 °C (5/6 because of
the upper switching point of the cooling, see also Sensor settings ->Hysteresis)

Table of Contents

Other manuals for GHL ProfiLux 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GHL ProfiLux 4 and is the answer not in the manual?

GHL ProfiLux 4 Specifications

General IconGeneral
ModelProfiLux 4
CategoryController
Power Supply12V DC
pH Ports2
Redox Ports1
Conductivity Ports1
Level Ports4
Digital Inputs4
12V Outputs4
Real-time clockYes, with battery backup
Digital Outputs4
ExpandableYes
ConnectivityUSB, Wi-Fi, LAN
DisplayGraphic LCD display
Expansion Slots4
Processor32-bit
Channels16
Operating Temperature0°C to 50°C