9 – 9
9.7 Command Error Messages and Their Causes
If any of the following command errors occur, they are nearly always caused by one of the reasons
below:
(1) The software configuration regarding the output device has been changed: or
(2) The plotter’s interface conditions have been changed.
When a command error occurs, therefore, first check the three corresponding points below:
(1) Configure the application software so that it can control the cutting plotter.
(2) Specify the application software's interface conditions to the correct settings.
(3) Specify the cutting plotter interface conditions to the correct settings.
Error messages in GP-GL command mode
Error message Cause Solution
→ Press the ENTER key.
→ Configure the software to
drive your plotter.
Ensure that the software’s
interface conditions are cor-
rectly set.
→ Ensure that the plotter’s in-
terface conditions are set
to match those of the soft-
ware.
→ Configure the software to
drive your plotter.
Ensure that the software’s
interface conditions are cor-
rectly set.
→ Ensure that the plotter’s in-
terface conditions are set
to match those of the soft-
ware.
The plotter received an unrecogniz-
able command.
• Noise was input to the plotter upon
execution of the software applica-
tion.
• The software configuration regard-
ing the output device has been
changed.
• The plotter’s interface conditions
have been changed.
A command was received with an
incorrectly specified terminator.
• The software configuration regard-
ing the output device has been
changed.
• The plotter’s interface conditions
have been changed.
ERROR 1
COMMAND ERROR
ERROR 2
TERMINATOR ERROR
(1/2)