Hantek TO1154D User Manual

Hantek TO1154D
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Tablet1000 series
Tablet oscilloscope
User Manual
2022.05

Table of Contents

Other manuals for Hantek TO1154D

Question and Answer IconNeed help?

Do you have a question about the Hantek TO1154D and is the answer not in the manual?

Hantek TO1154D Specifications

General IconGeneral
BrandHantek
ModelTO1154D
CategoryTest Equipment
LanguageEnglish

Summary

Safety requirements

Summary of general security issues

Key safety precautions to prevent injury and product damage. Read before use.

Product features

Quick start

Preparation before use

Essential steps before operating the oscilloscope, including power and initial checks.

Connect the power supply

Guide on connecting the power source and ensuring sufficient battery charge for operation.

Probe compensation

Procedure for calibrating probes to ensure accurate measurements and waveform display.

Set the horizontal system

Adjust the horizontal displacement

How to shift the waveform trigger point horizontally on the display.

Adjust the horizontal time base (time/grid)

Setting the time scale per grid for waveform analysis and zoom.

Set the vertical system

Adjust the vertical sensitivity

Setting the voltage scale per grid for optimal waveform amplitude viewing.

Adjust the vertical offset

Positioning the waveform vertically relative to the screen's center.

Channel coupling

Selecting AC, DC, or Ground coupling to filter signal components.

20M bandwidth limit

Applying bandwidth limiting to reduce high-frequency noise in measurements.

Probe

Manually setting the probe attenuation ratio for accurate amplitude readings.

Mathematical operations

Algebraic operation

Performing addition, subtraction, multiplication, and division on channel signals.

FFT operation

Converting time-domain signals to frequency-domain using Fast Fourier Transform.

Trigger oscilloscope

Trigger level

Setting the voltage threshold for triggering waveform acquisition.

Trigger data source

Selecting the input channel (CH1-CH4) for trigger signal detection.

Trigger mode

Choosing between Normal, Automatic, and Single trigger modes for stable display.

Trigger hold-off

Setting a delay after a trigger event to prevent re-triggering on subsequent events.

Trigger type

Selecting trigger conditions based on waveform edges, pulse width, video, slope, or timeout.

Edge-triggered

Triggering based on the rising or falling edge of a signal at a specific voltage.

Measure

Acquisition

Calibration

Multimeter

Signal source

Fault handling

Related product manuals