12 - Fault finding
12.5
49 49 Warning Output failing to sect 12 Detected by H-bridge on I2C bus Output failing to sect 12
50 50 Warning Output failing to sect 13 Detected by H-bridge on I2C bus Output failing to sect 13
51 51 Warning Output failing to bypass Output failing to bypass
52 52 Warning Electronic fuse 1 is on Measurement of voltage drop over electrothermal
fuse.
53 53 Warning Electronic fuse 2 is on Measurement of voltage drop over electrothermal
fuse.
54 54 Warning Electronic fuse 3 is on Measurement of voltage drop over electrothermal
fuse.
55 55 Warning Electronic fuse 4 is on Measurement of voltage drop over electrothermal
fuse.
56 56 Warning
RinseTank not full When main tank has been filled and rinse tank is empty. Remember to re-fill rinse tank.
57 57 Warning Main tank nearly empty Main tank empty (tank gauge value set in menu 2.5.2). Main tank is nearly empty. Consider distance left
before leaving field.
58 58 Warning Sections OFF If main ON/OFF is switched ON and one or more
sections
are OFF.
Note that one or more sections are switched OFF.
59 59 Warning
Spray pressure too high Spray pressure too high (limit set in menu 2.5.3.1). Decrease speed or change to nozzles with larger
capacity.
60 60 Warning Spray pressure too low Spray pressure too low (limit set in menu 2.5.3.2). Change to nozzles of less capacity or increase
speed if safe.
61 61 Warning Speed too high Speed too high (limit set in menu 2.5.5.1). Decrease speed. Pressure will be too high.
62 62 Warning Speed too low Speed too low (limit set in menu 2.5.5.2). Increase speed if safe. Pressure will be too low.
63 63 Warning Application volume too high Application volume too high (% limit set in menu). Increase speed if safe or change nozzle size.Check
regulation valve hoses and filters.
64 64 Warning Application volume too low Application volume too low (% limit set in menu). Decrease speed or change nozzle size. Check
regulation valve.
65 65 Warning Fan speed too high Fan speed too high (limit set in menu 2.5.4.1). Reduce fan speed
66 66 Warning Fan speed too low Fan speed too low (limit set in menu 2.5.4.2). Increase fan speed
67 67 Warning PTO speed too low PTO rev. too low (limit set in menu). Increase PTO speed
68 68 Warning PTO speed too high PTO rev. too high (limit set in menu). Decrease PTO speed
69 69 Warning Ladder not up Raise ladder, to avoid damage to ladder or crop.
70 70 Warning Wind Speed too high Wind Speed too high (limit set in menu). Stop spraying or consider other nozzle types like
HARDI® LowDrift.
71 71 Warning Air Temperature too high Air Temperature too high (limit set in menu). Stop spraying or consider other nozzle types.
72 72 Warning Air temperature too low Air Temperature too low (limit set in menu). Air Temperature too low
73 73 Warning RH too high RH too high (limit set in menu). Relative humidity too high
74 74 Warning RH too low RH too low (limit set in menu). Relative humidity too low
75 75 Warning Opt. sensor 1 too high Limit set in menu. This will be help text
76 76 Warning Opt. sensor 1 too low Limit set in menu. This will be help text
77 77 Warning Opt. sensor 2 too high Limit set in menu. This will be help text
78 78 Warning Opt. sensor 2 too low Limit set in menu. This will be help text
79 79 Warning Opt. sensor 3 too high Limit set in menu. This will be help text
80 80 Warning Opt. sensor 3 too low Limit set in menu. This will be help text
81 81 Warning Opt. sensor 4 too high Limit set in menu. This will be help text
82 82 Warning Opt. sensor 4 too low Limit set in menu. This will be help text
83 83 Reminder Aborted by keypress Upon press of softkey AutoWash is Aborted by keypress.
84 84 Reminder AutoWash completed When program is completed AutoWash is completed
ID Pr Type Text at display detail Criteria for fault
Operations disabled
Full screen Help text

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hardi HC6500 and is the answer not in the manual?

Hardi HC6500 Specifications

General IconGeneral
BrandHardi
ModelHC6500
CategoryController
LanguageEnglish

Related product manuals