  • S
    Sandra JacksonSep 1, 2025
    Why am I experiencing time loss with my HellermannTyton Autotool 2000 CPK Tools?
    • C
      Carmen ShahSep 1, 2025
      If your HellermannTyton Tools are experiencing time loss, the back-up battery for the clock in the power pack has likely discharged. Change the back-up battery.
  • C
    Carlos ShortSep 12, 2025
    What to do if HellermannTyton Power Tool shows 'Time loss'?
    • D
      David TurnerSep 12, 2025
      If the HellermannTyton Power Tool displays 'Time loss', it indicates that the back-up battery in the power pack is dead. Replace the back-up battery and press the Reset button.
  • J
    Jack MorrisAug 30, 2025
    What does 'Error, binding force' mean on HellermannTyton Autotool 2000 CPK?
    • N
      Nathaniel SuttonAug 30, 2025
      If your HellermannTyton Tools display shows 'Error, binding force', the specified binding force is not being achieved. Check the binding.
  • F
    friedmanjesseSep 14, 2025
    How to prevent loops from forming with HellermannTyton Industrial Electrical?
    • V
      Vanessa ChangSep 14, 2025
      Loops forming during the binding process with your HellermannTyton Industrial Electrical can be caused by several factors. It may be due to an unsuitable bundle diameter, the tie advancer not being in the correct position, a faulty spring in the upper jaw, or a blocked lower jaw. Here are some possible solutions: * Use a suitable bundle diameter. * Check the position of the tie advancer. * Check upper jaw flap in upper jaw with spring. * Check lower jaw and remove any blockage.
  • T
    Tammy EdwardsSep 14, 2025
    Why does my HellermannTyton Industrial Electrical show an error, drum?
    • S
      scottmurphySep 14, 2025
      The 'Error, drum' message on your HellermannTyton Industrial Electrical indicates that the cable tie bandoleer is pulled in at an angle, or the roller lever drum is jammed or defective. To fix this, push the actuator for the bandoleer cutter to the left and open the gate. Open the two transparent service flaps at the gate. Remove any cable-tie residues. Open the roller lever drum and turn the drum to the correct position. Then, press the Reset button and close the gate. Finally, load a new cable tie bandoleer.
  • L
    Luis KruegerSep 18, 2025
    What causes 'Error, front cap' on HellermannTyton Industrial Electrical?
    • R
      Rachel McclureSep 19, 2025
      The 'Error, front cap' message on your HellermannTyton Industrial Electrical can be caused by residues of cable ties trapped behind the front cap, or the level sensor being busy. To resolve this, clean the front sensor and carefully remove any cable-tie residues.
  • J
    James DuarteSep 23, 2025
    Why is binding not possible and the cable tie shoots straight out on my HellermannTyton Industrial Electrical?
    • S
      Samuel AbbottSep 23, 2025
      If binding is not possible and the cable tie shoots straight out on your HellermannTyton Industrial Electrical, it means that the upper jaw is blocked. To fix this, check the upper jaw and remove any blockage.
  • R
    Robert MedinaAug 27, 2025
    What causes 'Error, start position' on HellermannTyton Autotool 2000 CPK, and how can I fix it?
    • B
      Becky FletcherAug 27, 2025
      If your HellermannTyton Tools display shows 'Error, start position', it may be because the AT2000 CPK is not in the start position. Push the actuator for the bandoleer cutter to the left. Other possible solutions include opening and closing the gate, carefully removing any cable-tie residues, and pressing the Reset button.
  • B
    Benjamin RodriguezAug 26, 2025
    How to troubleshoot 'Error, drum' on HellermannTyton Autotool 2000 CPK?
    • M
      michaelafisherAug 26, 2025
      If your HellermannTyton Tools display shows 'Error, drum', it could be because the cable tie bandoleer is pulled in at an angle. Refer to the instructions for opening the two transparent flaps at the gate. Another possibility is that the roller lever drum is jammed or defective, in which case you should open the roller lever drum and turn the drum to the correct position.
  • B
    brianpayneAug 25, 2025
    What to do if HellermannTyton Autotool 2000 CPK display 'Error, gate'?
    • B
      Brittany CookAug 26, 2025
      If your HellermannTyton Tools display shows 'Error, gate', it may be because the drum is not in the correct position. To resolve this, open the gate and turn the drum to the correct position. Alternatively, the gate may simply be open; in that case, close it.

HellermannTyton Autotool 2000 CPK Specifications

General IconGeneral
TypeAutotool 2000 CPK
Application MethodPneumatic
For Cable Diameter Max.20 mm
Bundling Diameter max.20 mm
Tensile Strength min.80 N
TensioningAutomatic
Tension ForceAdjustable
Tie Width4.5 mm
Cable Tie Width4.5 mm
Material ShortcutPA66
Operating Temperature-40°C to +85°C
Tool IncludedYes
Pack Quantity1
Cutting MechanismAutomatic
Cutting SystemFlush cut
Power SupplyPneumatic
Operating Pressure6 bar
MaterialNylon 6.6