Chapter 13 Specifications
260
(10)Delay Setting
Operation Adjusts the time for measurement to stabilize by inserting a waiting period after
using the OVC or the auto-range function to change the measurement current
or after the TRIG signal.
Preset: Integration starts after the factory-default time (which varies with the
range) elapses.
User-set: Integration starts after the specified time elapses (for all ranges).
Setting Preset (internal fixed value)/ user-set (set value)
Delay setting range 0 ms to 9999 ms
Default setting Preset/ 0 ms
Preset delay value (internal fixed) (unit: ms)
LP OFF
LP ON
Range
100 M range
high-precision
mode
Measure-
ment cur-
rent
Delay
OVC: OFF OVC: ON
10 m
75 25
100 m
High 250 25
Low 20 2
1000 m
High 50 2
Low 5 2
10
High 20 2
Low 5 2
100
High 170 2
Low 20 2
1000
170 2
10 k
180
100 k
95
1000 k
10
10 M
1
100 M ON
500
100 M OFF
1
1000 M OFF
1
Delay