170 DR4300 Circular Chart Recorder Product Manual 4/00
Step Action Graphic
9
To fine-tune the alignment of the pen, press the raise switch
SW4 or lower switch SW3 until the pen tip is aligned with the
100 % line on the chart.
Approximately 10 seconds after the last press of the raise or
lower switch the pen will move downscale as described in
Step 2.
See Figure 3-1 for the location of SW3
and SW4.
10
To exit the pen alignment cycle place SW5 to the run
position (toward the bottom of the board). Pen will return to
normal operation.