EasyManua.ls Logo

Honeywell FIRE-LITE MS-10UD Series - Index

Honeywell FIRE-LITE MS-10UD Series
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
130 MS-5UD & MS-10UD Series Manual — P/N 52626:C7 6/12/2018
Index
Numerics
10 Zone Main Circuit Board
10
24 Hour Test Time
81
4XTMF
121
installation
33
see also Transmitter module
18
,
33
5 Zone Main Circuit Board
9
A
AC Loss Delay
68
AC power
23
AC power rating
13
AC power requirements
110
ACC audio message
55
,
61
accessories
18
Account Code
80
ACK
see also Acknowledge
13
Acknowledge
13
Acknowledge/Step
17
,
96
Ademco
contact ID format
113
Adjective
list
62
multiple entries
64
Adjective/Noun
62
alarm
97
piezo pulse rate
17
alarm relay
12
,
28
contact rating
14
Alarm Silence
13
,
17
,
96
alarm verification
56
,
100
,
101
ANN-80(C)
38
ANN-BUS
guidelines
35
ANN-I/O
LED zone assignments
72
ANN-LED
45
,
46
,
48
ANN-RLY
46
ANN-SEC option card
34
applications
12
Autosilence
101
NAC
66
auxiliary power
27
Auxiliary Trouble Input
14
B
backbox
dimensions
18
mounting
21
Backup Reporting
77
Banner
67
setting
69
battery
18
,
23
precautions
23
rating
13
battery box
18
mounting
22
,
23
battery calculations
112
baud rate
93
BB-55F
see also battery box
18
buttons
see also control buttons
13
C
cabinet
mounting
21
CAC-5X
25
installation
31
call limit
50
,
90
Canadian Applications
20
Canadian Option
67
,
70
Central Station
75
,
109
account code
80
communications
106
phone number
82
Phone Numbers
78
Central Station/Remote Station Reporting
119
charger capacity
13
Charger Disable
67
circuits
12
Class A
18
,
25
,
31
Class A Converter Module
18
installation
31
Class B
12
,
13
,
24
Clock Format
70
Coded Operation
100
coding
NAC
64
two stage operation
65
combination circuit
26
combination waterflow/supervisory
26
requirements
26
wiring
26
communications format
83
compatibility
see also device compatibility
12
contact ID
113
control buttons
13
,
96
controls
17
current
nonresettable power
27
resettable power
27
total output
26
current requirements for system
110
,
111
D
DACT
onboard
75
Date setting
70
Daylight Savings Time
70
Default Programming
127
description
12
detector label
63
Detector
adding description
62
enable/disable
54
device compatibility
12
dialer runaway
50
,
90
Digital Communicator
19
dimensions
backbox
18
Downloading
108
,
109
dress panel
12
,
18
Drill
13
,
17
,
96
E
earth ground
23
edit
detector screens
53
Enable/Disable
zone
54
End-of-Line resistor
IDC
14
,
25
,
26
NAC
14
,
27
Enter key
52
Erase History
92
Error Checking
109
event code classification
113
event codes
84
exiting
programming
51
,
52
Read Status
51
,
52
F
fail-safe
trouble relay
28
features
12
Form-C
see also relay
12
freeze
24
freeze signal
see also smoke detector monitoring
12
G
guidelines
35
H
Hazard Condition
99
History
91
erase
92
Maintenance Level
94
view events
91
I
I3 detectors
24
IDC
12
,
13
,
24
alarm current
14
compatibility
24
End-of_Line resistor
26
End-of-Line resistor
14
,
25
maximum loop resistance
14
,
24
short circuit current
14
standby current
14
wiring
25
indicators
17
see also LED
13
Initiating Device Circuit
12
,
13
,
24

Table of Contents

Related product manuals