61 ST 800 Pressure Transmitter User’s Manual Revision 15
Menu item shows the current
Firmware version of the
device. X = any numeric value
Menu to
select from
list
to enter
Menu item shows the current
Firmware version of the
sensor. X = any numeric value
Menu to
select from
list
to enter
Enter a value for damping of
the device output. Entries may
be any value from 0.00 to
32.00 seconds.
Press to
enter menu
selection
to select
number.
to enter and
shift to the
next digit to
the right
СтдСкан (STDSOR)
БыстСкн (FASTSOR)
Filter Performance: Configure
the desired performance for
the Output Speed of Response
Filter. Select from: Standard
SOR: excellent speed of
response to input changes with
optimal noise performance
Fast SOR: fastest speed of
response to input changes
Press to
enter menu
selection
Menu to
select from
list
to enter
Откл (DISABLE)
Вкл (ENABLE)
NAMUR:select to enable or
disable the NAMUR option
for effect on output signal.
Press to
enter menu
selection
Menu to
select from
list
to enter
Англ (ENGLISH)
Русский (RUSSIAN)
Language selection: Select
English or Russian option to
show display in selected
language.
Press to
enter menu
selection
Menu to
select from
list
to enter