Figure 38 Memory alarm notification and alarm-removed notification
To set memory thresholds:
Step Command Remarks
1. Enter system view.
system-view N/A
2. Set free-memory
thresholds.
memory-threshold [ slot slot-number ]
minor minor-value severe severe-value
critical critical-value normal normal-value
The defaults are as follows:
• Minor alarm threshold—96 MB.
• Severe alarm threshold—64 MB.
• Critical alarm threshold—48 MB.
• Normal state threshold—128
MB.
3. Set the memory
usage threshold.
memory-threshold usage
memory-threshold
By default, the memory usage
threshold is 100%.
Configuring the temperature alarm thresholds
The device monitors its own temperature through temperature sensors. You can set a low temperature
threshold, high-temperature warning threshold, and high-temperature alarming threshold.
When the temperature drops below the low temperature threshold or reaches the high-temperature
warning threshold, the device logs the event and sends out a log message and a trap.
When the temperature reaches the high-temperature alarming threshold, the device logs the event and
notifies users by repeatedly sending log messages and by setting the LEDs on the device panel.
To configure the temperature alarm thresholds:
Ste
Command
Remarks
1. Enter system view.
system-view N/A