Uplink interface and uplink 
An uplink interface, also known as an external interface, is the interface through which an NPV switch 
connects to the core switch. It can be an FC interface, FC aggregate interface, or VFC interface, both of 
which must be configured to operate in NP mode. 
An uplink is a link from an NPV switch to the core switch. 
When the uplink becomes operational, the NPV switch sends a fabric login (FLOGI) packet to the core 
switch for registration. The core switch assigns the uplink interface (NP_Port) an FC address. Then, the 
NPV switch registers itself with the name server on the core switch. When receiving a packet from a node, 
the NPV switch performs the following operations: 
•  Forwards the packet to the core switch through the mapped uplink interface. 
•  Passes the response packet from the core switch to the node through the downlink interface. 
Downlink-to-uplink interface mappings 
NPV switches automatically map downlink interfaces to uplink interfaces. Before a downlink interface is 
brought up, the NPV switch maps it to the uplink interface to which the minimum number of downlink 
interfaces is mapped. 
Typically, automatic mapping can meet your requirements. When a downlink interface must be 
connected to a fabric through the specified uplink interfaces, you can manually map the uplink interfaces. 
After you configure the mapping, the downlink interface can be mapped to only the configured uplink 
interfaces. If none of the configured uplink interfaces is operational, the downlink interface cannot be 
operational. 
A configured mapping selects the uplink interface with the minimum load from configured uplink 
interfaces and then maps the downlink interface to it. 
After a mapping is established, all traffic from the downlink interface is forwarded through the uplink 
interface. 
Disruptive load balancing 
When a new uplink interface becomes operational, the NPV switch does not perform a remapping for 
load balancing. In the event of remapping, the NPV switch reinitializes the downlink interface. Then, the 
node connected to the downlink interface registers with the core switch again. This causes traffic 
interruption to the node. 
You can trigger a remapping by using commands for better load balancing. In this case, the NPV switch 
reinitializes all downlink interfaces. 
NPV configuration task list 
Tasks at a 
lance
Remarks
(Required.) FC and FCoE configuration guidelines
 
Configuring the switch to operate in NPV mode.
(Required.) Configuring uplink interfaces and downlink 
interfaces 
N/A