207
[SwitchC] interface ten-gigabitethernet 1/0/8
[SwitchC-Ten-GigabitEthernet1/0/8] priority-flow-control enable
[SwitchC-Ten-GigabitEthernet1/0/8] priority-flow-control no-drop dot1p 3
[SwitchC-Ten-GigabitEthernet1/0/8] qos trust dot1p
[SwitchC-Ten-GigabitEthernet1/0/8] quit
4. Configure FC and FCoE:
# Configure the switch to operate in FCF mode.
[SwitchC] fcoe-mode fcf
# Enable the fabric configuration feature in VSAN 100. By default, the fabric configuration feature
is enabled.
[SwitchC] vsan 100
[SwitchC-vsan100] domain configure enable
# Set the priority to 1 for the switch, so the switch can be elected as the principal switch.
[SwitchC-vsan100] priority 1
# Configure the domain ID as 1 for the switch.
[SwitchC-vsan100] domain-id 1 preferred
Non-disruptive reconfiguration or isolating the switch may be performed. Continue?
[Y/N]:y
# Enable FSPF globally.
[SwitchC-vsan100] fspf enable
[SwitchC-vsan100] quit
# Change Ethernet interface Ten-GigabitEthernet 1/0/1 into FC interface FC 1/0/1.
[SwitchC] interface ten-gigabitethernet 1/0/1
[SwitchC-Ten-GigabitEthernet1/0/1] port-type fc
# Configure the mode of interface FC 1/0/1 as F.
[SwitchC-Fc1/0/1] fc mode f
# Configure interface FC 1/0/1 to autonegotiate the speed.
[SwitchC-Fc1/0/1] speed auto
# Configure interface FC 1/0/1 to trust the 802.1p priorities included in incoming packets.
[SwitchC-Fc1/0/1] qos trust dot1p
# Assign interface FC 1/0/1 to VSAN 100 as an access port.
[SwitchC-Fc1/0/1] port access vsan 100
# Enable FSPF for interface FC 1/0/1.
[SwitchC-Fc1/0/1] undo fspf silent vsan 100
[SwitchC-Fc1/0/1] quit
# Create interface VFC 10.
[SwitchC] interface vfc 10
# Configure the mode of VFC 10 as E.
[SwitchC-Vfc10] fc mode e
# Bind VFC 10 to Layer 2 aggregate interface 1.
[SwitchC-Vfc10] bind interface bridge-aggregation 1
# Assign VFC 10 to VSAN 100 as a trunk port.
[SwitchC-Vfc10] port trunk vsan 100
# Enable FSPF for VFC 10.
[SwitchC-Vfc10] undo fspf silent vsan 100