Removal and replacement procedures 30
HP BladeSystem c7000 power supply or power
supply blank
CAUTION: This procedure provides instructions for replacement of a failed part only. To change
the configuration of components, see the appropriate HP BladeSystem c-Class enclosure setup
and installation guide.
CAUTION: Do not mix HP 2250W, HP 2400W High Efficiency, HP BL7000 2400W Platinum,
or -48vDC power supplies in one enclosure. Install only one type of power supply in a single
enclosure.
NOTE: To access all power supply bays, slide the HP BladeSystem Insight Display to the right or
left.
To remove the component:
1. Press the release button.
2. Pull down the handle.
3. Remove the power supply or the power supply blank.
CAUTION: For best cooling practices, do not operate the enclosure for extended periods with
more than one component or blank removed. When removing an active component, replace it
with a blank.
To replace the component, reverse the removal procedure.

Table of Contents

Other manuals for HP BladeSystem c7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP BladeSystem c7000 and is the answer not in the manual?

HP BladeSystem c7000 Specifications

General IconGeneral
Form Factor10U
Number of Bays16
Redundant PowerYes
Redundant FansYes
Maximum Blade Servers16 half-height or 8 full-height
Operating Temperature10° to 35°C (50° to 95°F)
Power SuppliesUp to 6
Cooling Fans10
ManagementOnboard Administrator
Interconnect ModulesUp to 8
Networking OptionsEthernet, Fibre Channel, InfiniBand
CompatibilityHP ProLiant and Integrity server blades
Relative Humidity10% to 90% (non-condensing)