IP Routing Features
Configuring DHCP Relay
Relay agents without Option 82 can exist in the path between Option 82
relay agents and an Option 82 server. The agents without Option 82 will
forward client requests and server responses without any effect on Option
82 fields in the packets.
If the routing switch cannot add an Option 82 field to a client’s DHCP re-
quest due to the message size exceeding the MTU (Maximum Transmis-
sion Unit) size, then the request is forwarded to the DHCP server without
Option 82 data and an error message is logged in the switch’s Event Log.
Because routing is not allowed between the Management VLAN and
other VLANs, a DHCP server must be available in the Management
VLAN if clients in the Management VLAN require a DHCP server.
If the Management VLAN IP address configuration changes after
mgmt-vlan has been configured as the remote ID suboption, the
routing switch dynamically adjusts to the new IP addressing for all
future DHCP requests.
The Management VLAN and all other VLANs on the routing switch
use the same MAC address.
3-62

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2910al Switch and is the answer not in the manual?

HP ProCurve 2910al Switch Specifications

General IconGeneral
ModelHP ProCurve 2910al Switch
LayerLayer 3
Jumbo Frame SupportYes
Power DeviceInternal power supply
VLAN SupportYes
Power Supply100-240 VAC, 50/60 Hz
Ports24 or 48 x 10/100/1000 ports
Uplink Ports4 x SFP (mini-GBIC)
StackingYes
MAC Address Table Size32000 entries
Routing ProtocolRIP, OSPF, BGP, IGMP
Remote Management ProtocolSNMP 1, RMON 1, RMON 2, RMON 3, RMON 9, Telnet, SNMP 3, SNMP 2c, HTTP, TFTP
FeaturesVLAN, QoS, IPv6, ACLs
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3af
Operating Temperature0 to 45°C
Operating Humidity15% to 95% (noncondensing)
Power over Ethernet (PoE)PoE+ (802.3at) on PoE+ models, PoE (802.3af) on PoE models