OPERA TING INSTRUCTIONS
I~
~
__________________________________________
~II
I
2.0
INTRODUCTION
This section
of
the
manual describes how to operate the PICDIAG.
The primary function
of
the PICDIAG
is
to test and diagnose the HP
3000
Series
37
Peripheral Interface
Card. The
PICDIAG will isolate faults to
the
component level wherever possible.
You control test selection, looping, error handling, and printing messages.
2.1
TEST
SELECTION
The PICDlAG
is
divided
into
tests
that
can be
run
individually or in various combinations.
Use
the STATE command to list which tests and commands are
currently
selected. When the PICDIAG
is
in the default configuration, the STATE command will display the following message:
PICDIAG
STATUS:
PATH: X X
CHANNEL: X X
EEPR:
ON
EEPS:
ON
ENPR:
ON
LOOP:
OFF
PRINT:
OFF
TRACE:
OFF
Sections
Selected:
1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,
23,25,28,29,30,32,33,34,35,36,37,39,41,42,43,44,45
To change
the
test selection, type TEST,
then
use a
'-'
in
front
of
the
test number(s) to be deleted, a '+' in
front
of
the test number(s) to be added, or simply
the
test number(s) to be executed.
EXAMPLE:
TEST -
3,6
deletes test sections 3 and 6
TEST
+ 1,5,6 adds test sections I,
5,
and 6
TEST
1/5,8
executes test sections 1-5, and 8
Test
41
through
45 require a second
PIC.
SEP 84
2-1