Operating Instructions
2.6
HOW
TO
CONFIGURE MDIAG37
You
can
configure and reconfigure the diagnostic according to your needs.
MDIAG performs initialization and Section
I,
followed by a prompt for
an
operator command. If you are
going
to
use
the
default
commands (indicated with an asterisk in Table 2-1), type
GO
in response
to
the
prompt.
If
you
want
to
reconfigure
the
diagnostic, you can do
so
at
this point
or
after
you
interrupt
the
diagnostic. Table 2 - 1 provides
the
a vaila ble commands.
COMMAND
EEOPP*
EEPS*
ENDP*
EXIT
GO
HELP
LDS
LOOPTST(n)
LOOPERR
SEP
84
2-4
I
Table
2-1.
DIAGNOSTIC COMMANDS
NAME DESCRIPTION
Enable End
Of
Program Pause allows end of program pause
Enable
Error
Pause
halts
after
error
occurs
Enable
Non-error
Display
allows
information
messages
I
Exits
the
diagnostic
returns
to DUS
resumes program
at
current
step
I
allows diagnostic
to
continue
at
current
step
lists commands
I
lists available commands
with
a brief
description
I
List Diagnostic Status
I
Lists
the
following information:
I
which test sections are enabled
ENDP flag:
true
or false
EEPS flag:
true
or
false
EEOPP flag:
true
or
false
LOOPTST flag:
true
or false
LOOPERR flag:
true
or false
PEMP flag:
true
or false
number
of
executed diagnostic passes
Loop on
current
Test list
May
enter
a repetition factor. If a
parameter
is
blank,
the
loop continues
until
LOOPOFF
is
set.
Loop on test
with
Error
Loops on failed test section. Halt
i
LOOPERR with
CNTRL-Y
I
LOOPERR
is
not available in test
I
sections
I,
8,
and
9.
I
I

Table of Contents