Test Descriptions
3.3
TEST
SECTION 3
Address
Test
Step 31. Address Test
--
This step will write
the
"exclusive or" of the bank and address
of
every available
location into itself. Each location
is
then
read and verified. This procedure
is
repeated, using
the compliment
of
the
"exclusive or" of
the
bank and address
of
every location as data.
If
this
test fails,
the
unique address capability may have failed.
The following messages will appear during test execution:
Begin
Section
3
Begin
Step
31
All
of
tested
memory
has
been
written
Pass
1
completed
- Begin
Pass
2
All
of
tested
memory
has
been
written
Step
31
completed
End
of
Section
3
Error
message:
Expected:
%XXXXXX;
Received:
%YYYYYY
Address =
r.ZZZZZZ
Bank = W
Board = A
Where:
XXXXXX
= data expected in octal
YYYYYY
= data received
in
octal
ZZZZZZ
= address
of
error
in octal 0 < = Z < " 1 77 7 77
W = bank with
error
0 < = W < =
31
A = 0/1
SEP 84
3-5