Event
code
Message text and description Details and solution
2005 Robotic spooling cable failure Ensure that the spooling cable is fully seated in
the base module and correctly connected to the
robotic assembly.
2006 Cable to spooling mechanism has failed.
2007 Move command failed due to spooling
mechanism failure
2008 Exchange cartridge failed due to
spooling mechanism failure
2009 Library test failed due to robotics
problem
• Review the test requirements, address any
issues, and then retry the test.
• Clear any obstructions from the bottom of
the library. For instructions, see .
2010 Library test failed due to spooling
mechanism defect
Ensure that the spooling mechanism is fully
seated in the base module and installed
correctly with the robotic assembly.
2011 A drive power board has failed. Because
of this failure, some drives might be
powered off.
Each module has two drive power boards,
which are located under the chassis fan. The
left drive power board provides power for the
upper three half-height tape drive bays in the
module. The right drive power board provides
power for the lower three half-height tape drive
bays in the module. See the event details to
determine which drive power board failed.
1. Ensure that the drive power boards are fully
seated in the module.
2. Reboot or power cycle the library.
2012 Multiple bottom covers detected. Remove all bottom covers except for the bottom
module in the library.
2013 Multiple top covers detected. Remove all top covers except for the top
module in the library.
Table Continued
Event codes 199