Event
code
Message and description Details and solution
4044 One of the library tests failed because a
source element or destination element is not
accessible.
The library either could not find the source
cartridge or the destination element was
unexpectedly full. This error can happen if a
cartridge in the destination element has an
unreadable barcode label.
1. See the event details to find the source
and destination elements.
2. Open the magazine and inspect the
source and destination drives or slots.
3. Unless the library is configured not to
use barcode labels, verify that all
cartridges have a high-quality proper
barcode label.
4046 The drive configuration failed because of
missing DPF license.
Disable path failover or install the necessary
failover license.
4047 The drive configuration failed because of
missing CPF license.
4048 The drive configuration failed because of
unsupported BDPF feature selected.
Disable basic path failover for this drive or
replace the drive with one supporting this
feature.
4049 The drive configuration failed because of
unsupported BCPF feature selected.
4050 Basic datapath failover occurred. Check cabling and all network components
between the affected drive and host
computer.
4051 A new encryption key could not be created
because media is loaded in one or more
drives. Unload the media from all drives and
then retry the manual key creation again.
4052 A new encryption key could not be created
because media is loaded in one or more
drives. Unload the media from all drives and
then automatic key generation will occur
during the next scheduled time frame, or
generate a new key server token key
manually.
4053 Manual control path failover from active to
passive drive failed; partition may be
disconnected from host.
Check cabling and all network components
between the affected drive and host
computer.
Table Continued