Event
code
Message and description Details and solution
4070
Key not found on key server or MSL
Encryption Kit token.
Verify that the requested key is either
available on the key server or that the key
server token containing the requested key is
inserted and logged in.
4071 Power supply fan failed. Verify that the power supply fan is spinning
and ensure that there are no obstructions in
the fan.
4072 No cleaning cartridge in partition available
for auto cleaning.
When initiating a cleaning operation, the
library will use an unexpired cleaning
cartridge from the same partition as the tape
drive. If the partition does not contain an
unexpired cleaning cartridge, the library will
use an unexpired cleaning cartridge from an
unpartitioned area of the library. The library
will not use a cleaning cartridge from a
different partition. When enabling auto
cleaning, ensure that either each partition
has an unexpired cleaning cartridge or place
at least one unexpired cleaning cartridge in
an area that is not assigned to a partition.
The cleaning cartridge label must begin with
the letters “CLN” for the library to recognize
it as a cleaning cartridge. For more
information about auto cleaning, see
Configuring auto cleaning on page 109.
1. Verify that a properly labeled unexpired
cleaning cartridge is available in the
same partitions as the drives requesting
cleaning or in an unpartitioned area of
the library.
2. Perform a load and unload on any drives
that need cleaning to initiate
autocleaning.
4073 Medium source element empty. Check the source slot visually and rescan
inventory. Verify that the cartridge has a
valid and readable barcode label. Check the
source slot visually and rescan inventory.
Verify that the cartridge has a valid and
readable barcode label.
4074 Medium source element empty.
4075 Cartridge lost while extracting it from the
slot/drive.
Check the source element and ensure that
there are not obstructions in the pathway of
the robot.