Loading...
5. Remove the SD card board (5) and cable
Reverse this procedure to install the SD card board and cable.
Fingerprint reader module cable
To remove the ngerprint reader module cable, use this procedure and illustration.
The ngerprint reader module cable is available in the Cable Kit, spare part number M20105-001.
Before removing the ngerprint reader module cable, follow these steps:
1. Prepare the computer for disassembly (Preparation for disassembly on page 66).
2. Remove the service cover (Service cover on page 40), and then remove the following components:
1. Battery (see Battery on page 41)
2. Solid-state drives 3 and 4 (see Solid-state drives 3 and 4 on page 42)
3. Solid-state drive carrier (see Solid-state drives 3 and 4 on page 42)
4. Hard drive (see Hard drive on page 44)
5. Keyboard (see Keyboard on page 54)
6. Bottom case (see Bottom case on page 66)
Remove the ngerprint reader module cable:
1. Release the ZIF connector (1) to which the ngerprint reader module cable is connected, and then
disconnect the ngerprint reader module cable from the system board.
2. Release the ZIF connector (2) to which the ngerprint reader module cable is connected, and then
disconnect the ngerprint reader module cable from the ngerprint reader module.
70 Chapter 6 Removal and replacement procedures for authorized service provider parts ENWW