Drive numbering
Depending on the configuration, this server blade can support hard drives, SSDs, NVMe SSDs, and uFF drives (supported
in a SFF Flash Adapter) in the drive bays. Depending on the device installed, the bay number might be dierent.
Item Hard drive/SSD bay
numbering
uFF drive bay
numbering
NVMe drive bay numbering
1 1 1 and 101 1
2 2 2 and 102 2
Hot-plug drive LED definitions
Item
LED Status Definition
1 Locate Solid blue The drive is being identified by a host application.
Flashing blue The drive carrier firmware is being updated or requires an update.
2 Activity
ring
Rotating green Drive activity
O No drive activity
3 Do not
remove
Solid white Do not remove the drive. Removing the drive causes one or more of the logical
drives to fail.
O Removing the drive does not cause a logical drive to fail.
4 Drive
status
Solid green The drive is a member of one or more logical drives.
Table Continued