Power up the server blade
Removing and replacing the direct connect SATA cable
Replacing the access panel
Install the server blade
DIMM-processor compatibility
The installed processor determines the type of DIMM that is supported in the server blade:
• First-generation Intel Xeon Scalable processors support DDR4-2666 DIMMs.
• Second-generation Intel Xeon Scalable processors support DDR4-2933 DIMMs.
Mixing DIMM types is not supported. Install only the supported DDR4-2666 or DDR4-2933 DIMMs in the server blade.
Removing and replacing a DIMM
Procedure
1.
Power down the server blade.
2.
Remove the server blade.
3.
Place the server blade on a flat, level work surface.
4.
Remove the access panel.
5.
Remove both DIMM
bales.
IMPORTANT: When removing a DIMM
bale, do not remove the following options when installed on the DIMM
bale:
• M.2 enablement option (left DIMM bale)
• HPE Smart Storage Battery (right DIMM bale)
IMPORTANT: When removing the right DIMM bale, use the blue pull tab to disconnect the HPE Smart Storage
Battery cable from the system board.
6.
Remove the DIMM.
Removal and replacement procedures
49