EasyManua.ls Logo

HPE ProLiant DL345 Gen11 - Removing and replacing a Flexible Slot power supply; Prerequisites; About this task; Procedure

HPE ProLiant DL345 Gen11
341 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removing and replacing a Flexible Slot power supplyRemoving and replacing a Flexible Slot power supply
PrerequisitesPrerequisites
Before replacing a power supply, review the following:
Power supply warnings and cautions
DC power supply warnings and cautions
If you are replacing a DC power supply:
Make sure that you have a Phillips No.2 screwdriver available.
Identify the wire color and corresponding wire slots on the DC power supply:
Wire colorWire color DescriptionDescription Wire slotWire slot
Red Positive return wire RTN
Black Negative input wire -48V
Green + yellow Ground wire Ground
About this taskAbout this task
WARNING:WARNING: To reduce the risk of personal injury from hot surfaces, allow the power supply, power supply blank, or dual slot
power supply adapter to cool before touching it.
CAUTION:CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with
either a component or a blank.
ProcedureProcedure
1. Power down the server.
2. If installed, open the cable management arm.
3. To remove an AC power supply, do the following:
a. Release the power cords, wires, and cables from the strain relief strap.
HPE ProLiant DL345 Gen11 Server Service and Maintenance Guide 73

Table of Contents