9. Install the access panel.
10. Slide the server into the rack.
11. Connect the LAN segment cables.
12. Connect each power cord to the server.
13. Connect each power cord to the power source.
14. Power up the server .
The installation is complete.
Installing a 1U or high-performance heatsink
This procedure shows a standard heatsink as an example. The installation process is the same for all
heatsinks.
HPE recommends identifying the processor, heatsink, and socket components before performing
this procedure.
Prerequisites
Before installing this option, be sure that you have the following:
• The components included with the hardware option kit
• T-20 Torx screwdriver
Procedure
1. Observe the following alerts.
CAUTION:
To prevent possible server malfunction and damage to the equipment, multiprocessor
configurations must contain processors with the same part number.
CAUTION:
If installing a processor with a faster speed, update the system ROM before installing the
processor.
To download firmware and view installation instructions, see the Hewlett Packard Enterprise
Support Center website.
CAUTION:
THE CONTACTS ARE VERY FRAGILE AND EASILY DAMAGED. To avoid damage to the
socket or processor, do not touch the contacts.
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Do one of the following:
Installing a 1U or high-performance heatsink 123