EasyManua.ls Logo

HPE ProLiant DL385 Gen10 - Removing the Server from the Rack; Installing the Server into the Rack

HPE ProLiant DL385 Gen10
177 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removing the server from the rack
To remove the server from a Hewlett Packard Enterprise, Compaq-branded, Telco, or third-party rack:
Procedure
1. Power down the server.
2. Extend the server from the rack.
3. Disconnect the cabling and remove the server from the rack.
For more information, see the documentation that ships with the rack mounting option.
4. Place the server on a sturdy, level surface.
Installing the server into the rack
Procedure
1. Observe the following alert:
CAUTION:
Always plan the rack installation so that the heaviest item is on the bottom of the rack. Install the
heaviest item first, and continue to populate the rack from the bottom to the top.
2. Install the server and cable management arm into the rack. For more information, see the installation
instructions that ship with the rack rail system.
3. Connect peripheral devices to the server. For information on identifying connectors, see "Rear panel
components."
WARNING:
To reduce the risk of electric shock, fire, or damage to the equipment, do not plug telephone or
telecommunications connectors into RJ-45 connectors.
Removing the server from the rack 37

Table of Contents

Other manuals for HPE ProLiant DL385 Gen10

Related product manuals