HPE ProLiant DL385 Gen10 - Installing a Rear 3 LFF SAS;SATA Drive Cage

HPE ProLiant DL385 Gen10
177 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installing a rear 3LFF SAS/SATA drive cage
Before installing this option, the front bays must be fully populated with 12 LFF drives. High-performance
fans must be installed in all fan bays.
Prerequisites
Before installing this option, be sure that you have the following:
• T-10 Torx screwdriver
• The components included with the hardware option kit
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
•
Extend the server from the rack.
• Remove the server from the rack .
4. Remove the access panel.
5. If installed, remove the secondary riser cage. The secondary riser cage is not supported with a three-
bay LFF rear configuration.
6. Remove the rear wall blank.
94 Installing a rear 3LFF SAS/SATA drive cage