Installing a rear 3LFF SAS/SATA drive cage
Before installing this option, the front bays must be fully populated with 12 LFF drives. High-performance
fans must be installed in all fan bays.
Prerequisites
Before installing this option, be sure that you have the following:
• T-10 Torx screwdriver
• The components included with the hardware option kit
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
•
Extend the server from the rack.
• Remove the server from the rack .
4. Remove the access panel.
5. If installed, remove the secondary riser cage. The secondary riser cage is not supported with a three-
bay LFF rear configuration.
6. Remove the rear wall blank.
94 Installing a rear 3LFF SAS/SATA drive cage