Prerequisites
A storage controller and high-performance fans are required when installing this drive cage.
Procedure
1. Observe the following alerts.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
CAUTION:
To prevent damage to electrical components, properly ground the server before beginning any
installation procedure. Improper grounding can cause ESD.
2. Power down the server .
3. Do one of the following:
• Extend the server from the rack.
• Remove the server from the rack .
4. Remove the access panel.
5. Remove the air baffle.
6. Remove the fan cage.
7. Remove the blank.
8. Install the drive cage:
a. If drive blanks are installed in the drive cage assembly, remove the drive blanks. Retain the
drive blanks for use in empty drive bays.
b. Install the drive cage.
76 Hardware options installation