Appendix A Parameters Shenzhen Hpmont Technology Co., Ltd.
- 112 - HD3N Series User Manual V1.1
Function
Setting Range Default
Unit
Attribute Setting
d00.17 Setting rpm (rpm) 0 - 60000rpm *
d00.18 Runnig rpm (rpm) 0 - 60000rpm *
d00.19 Input voltage (V) 0 - 999V *
d00.20 Output voltage (V) 0 - 999V *
d00.21 Output current (A) Actual value, unit: 0.1A *
d00.22 Torque setting (%)
-250.0 - 250.0% (rated torque of
motor)
*
d00.23 Output torque (%) 0.0 - 300.0% (rated torque of motor) *
d00.24 Output power (kW) Actual value, unit: 0.1kW *
d00.25 DC busbar voltage (V) 0 - 999V *
d00.26
Input voltage of
potentionmeter (%)
0.0 - 100.0%
Valid when LED keypad adopted
*
d00.27 AI1 input (%) 0.0 - 100.0% *
d00.28
AI1 input (after
calculating) (%)
0.0 - 100.0% *
d00.29 AI2 input (%) 0.0 - 100.0% *
d00.30
AI2 input (after
calculating) (%)
0.0 - 100.0% *
d00.35
DI6 terminal pulse input
frequency (Hz)
0 - 10000Hz *
d00.36 AO1 output (%) 0.0 - 100.0% *
d00.37 AO2 output (%) 0.0 - 100.0% *
d00.38
High speed output pulse
frequency (Hz)
0 - 10000Hz *
d00.40 Setting line speed 0 - max output line speed *
d00.41 Reference line speed 0 - max output line speed *
d00.44 PID setting (%) -100.0 - 100.0% *
d00.45 PID feedback (%) -100.0 - 100.0% *
d00.46 PID tolerance (%) -100.0 - 100.0% *
d00.47 PID integral item (%) -100.0 - 100.0% *
d00.48 PID output (%) -100.0 - 100.0% *
d00.49 External count value 0 - 9999 *
d00.50 Input terminal status
Bit0 - Bit8 correspond to DI1 - DI6
0: Input terminals disconnect with
common terminals
1: Input terminals connect with
common terminals
*
d00.51 Output terminal status
Bit0 - Bit1 correspond to DO1 - DO2
Bit2 correspond to R LY1
0: Output terminals disconnect with
common terminals
1: Output terminals connect with
common terminals
*