User Guide v 1.0 — August 2018 Altanium Neo5
Remote Boost can be cancelled at any time by touching the Start or Stop buttons (only when
in the Trigger or ON/OFF modes).
---- X:XX:XX X:XX:XX Trigger System delays for specified time and then enters
Boost until the timer expires.
---- X:XX:XX 0:00:00 Trigger System delays for specified time and then enters
Boost indefinitely.
---- 0:00:00 0:00:00 ON/OFF System enters Boost until the input signal is not
active.
---- 0:00:00 X:XX:XX ON/OFF System enters Boost until the input signal is not
active or the timer expires.
---- X:XX:XX X:XX:XX ON/OFF System delays for specified time and then enters
Boost until the input signal is not active or the
timer expires.
---- X:XX:XX 0:00:00 ON/OFF System delays for specified time and then enters
Boost until the signal is not active.
---- ---- ---- Direct System enters Standby until the input signal is not
active. If the input signal is active when the system
is started, it will immediately go into Standby
mode.
Remote Boost Operational Description (Continued)
Manual
Time
Delay
Time
Remote
Time
Input
Mode
Operation - Boost Button Select