Output Mode — In the dialog box, you can choose what type of output mode that will be
used to control the zones. Choose zero cross or phase angle.
PCM - Priority Control — In the dialog box, select zone or system. In an abort condition Neo5
will remove power from the zone if the malfunctioning zone is set to Zone or go into stop
mode if the malfunctioning zone is set to system.
AMC — Automatic Manual Control (AMC). If the zones thermocouple fails, Neo5 will
automatically apply a manual power output percentage to heat the zone, if AMC is set to On.
Neo5 software will use a historical average to calculate the manual power output
percentage.
Earth Leakage Check — In the dialog box, set the earth leakage check to On or Off. The
default setting is On.