Preventive maintenance
4
124 811390 Operator Manual DynaMAX 550P/560P/575P Waterjet Pump
5. Turn ON the electrical main.
6. Turn the primary breaker disconnect lever on the electrical enclosure door to
ON.
7. The operator interface screen is on when the pump is energized.
8. Make sure that the L
OCAL/REMOTE key switch on the operation panel is set to LOCAL. Refer to
Operation panel on page 48 for information.
a. Push the C
ONTROLS ON button to turn on the control circuit in the pump.
b. The pump can not be turned on until the control circuit is on.
9. Turn
ON the pump in cooling mode.
10. The post-maintenance start program operates. Refer to Postmaintenance start procedure on
page 131.
11 . Monitor for leaks.