Product description
DynaMAX 550P/560P/575P Waterjet Pump Operator Manual 811390 33
Cooling loop
Compressing hydraulic fluid generates substantial heat that can cause damage to equipment and 
decrease the life of the fluid. Fluid that is too hot is thin, which accelerates wear on the parts, 
increases the formation of sludge, degrades the fluid, and decreases its lubrication and protective 
qualities. Increased temperature can mean that there is a problem with the cooling system.
The cooling loop keeps the hydraulic fluid at its optimum temperature.
Cooling loop for a water-cooled system (internal heat exchanger)
When the primary motor is operating, cooling water goes through the heat exchanger, transferring 
heat away from the hydraulic fluid to the cooling water.
Low-pressure water Hydraulic fluid
1
Utility panel: C
OOLING IN
Low-pressure supply water or water 
from a chiller goes to the heat exchanger.
2
Internal heat exchanger
3
Utility panel: C
OOLING OUT
Water from the heat exchanger goes to a 
chiller or a drain.
4
Hydraulic fluid tank
Hydraulic fluid goes from the tank to the 
gear pump (not shown). From the gear 
pump, the hydraulic fluid goes to the 
heat exchanger.
5
Hydraulic filter
The gear pump moves hydraulic fluid 
from the heat exchanger to the filter and 
then into the tank.