Specifications
7
DynaMAX 550P/560P/575P Waterjet Pump Operator Manual 811390 175
Supply water
The quality of the water supplied to the intensifier has a direct effect on the life of the intensifier and
the consumables. Bad water quality increases operating costs by causing unnecessary wear on
pump parts and shortening maintenance intervals. Mineral deposits can clog the cooling fins in the
heat exchanger.
Softened water is necessary for most systems. Get advice from a specialist for recommendations
for choosing a water treatment system. Reverse osmosis systems are available from Hypertherm.
Water quality
Refer to Test the water quality on page 93.
Water temperature
If the cooling water or the supply water temperature is higher than24°C(75°F), cool the water
before use. Water that is too warm can shorten high-pressure seal life.
Compressed air
Air pressure that is too low can prevent the bleed-down valve from closing and can cause the
intensifier to overstroke.
Air pressure that is too high can cause damage to the needle and the seat in the bleed-down valve.
Test Optimal range
pH 6.0 to 8.0
Silica (SiO
2
) Lower than 0.0015%
(15 ppm)
Water hardness Equal to or lower than 0.006%
(60 ppm / 3.5 grains per gallon)
Total dissolved solids (TDS) 0.0025% to 0.015%
(25 ppm to 150 ppm)
Minimum Maximum
Pressure 5.17 bar (75 psi) 8.27 bar (120 psi)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm DynaMAX 550P and is the answer not in the manual?

Hypertherm DynaMAX 550P Specifications

General IconGeneral
BrandHypertherm
ModelDynaMAX 550P
CategoryWater Pump
LanguageEnglish

Related product manuals