Installation
8
DynaMAX 550P/560P/575P Waterjet Pump Operator Manual 811390 217
Pressures
Water Manifold
Output
This shows the pressure coming out of the water manifold.
Minimum
Touch this field to open a keypad.
Enter the minimum pressure permitted before a fault occurs.
The setpoint is based on the pump
model.
DynaMAX 550P 2.0 bar (29 psi)
DynaMAX 560P 1.7 bar (25 psi)
DynaMAX 575P 1.5 bar (21 psi)
Hydraulic
Output
This shows the hydraulic pressure in the system.