Page #96 background imageLoading...
Page #96 background image
Preventive maintenance
4
96 811390 Operator Manual DynaMAX 550P/560P/575P Waterjet Pump
10. Engage the intensifier.
Intensifier
Every 500 hours
Repair the check valve and the low pressure
poppets.
Repair the high-pressure cylinders.
Replace the high-pressure seal cartridges.
Every 1,000 hours
Replace the high-pressure poppet assemblies.
Replace the low-pressure poppets.
Every 1,500 hours
Flip the high-pressure cylinders.
Every 3,000 hours
Replace the high-pressure cylinders.
Replace the check valve assemblies.
Every 6,000 hours
Replace the output adapters.
Replace the seal housing assemblies.
Every 6,000 hours
Replace the spacer tubes.
Repair the hydraulic center section.
CAUTION
To prevent causing damage or premature failure, use 2 wrenches when loosening or
tightening a high-pressure connection.
Always tighten fittings to the specified torque.
CAUTION
Do not use an adjustable wrench on high-pressure fittings.
Use clean hands when changing high-pressure parts.
To reduce downtime, Hypertherm recommends doing preventive maintenance on both
ends of the intensifier at the same time.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm DynaMAX 550P and is the answer not in the manual?

Hypertherm DynaMAX 550P Specifications

General IconGeneral
BrandHypertherm
ModelDynaMAX 550P
CategoryWater Pump
LanguageEnglish

Related product manuals