Preventive maintenance
4
78 811390 Operator Manual DynaMAX 550P/560P/575P Waterjet Pump
Hydraulic system
Check the hydraulic filter
Parts, tools, and materials
Do this task when the pump is running at operating temperature.
1. Use a standard screwdriver to remove the pump cover.
2. Make sure that the white indicator bar is not in the red zone.
Do this every work shift.
Replace the hydraulic filter:
Every 1,500 hours
When the white indicator bar stays in the red zone while the pump is at operating temperature
Refer to Replace the hydraulic filter element on page 80 for instructions.
1
2
1 White indicator bar
2 Red zone