Preventive maintenance
4
86 811390 Operator Manual DynaMAX 550P/560P/575P Waterjet Pump
Low-pressure water system
Examine the transport tubes
Make sure that the transport tube routing is correct.
Clean the Seal Maintenance Indicator tubes
The inner surfaces of the SMI tubes become dirty over time. Dirty tubes can cause a fluid monitoring
sensor error.
Parts, tools, and materials
Do this every 500 hours and when the high-pressure seals are replaced.
Do this every 500 hours and when the high-pressure seals are replaced.
Replace the tubes every 1,500 hours.
Good tube routing Bad tube routing
Replacement kit, SMI tubes,
DynaMAX 550P/560P/575P
Refer to the DynaMAX standard tool kit.