Operation
3
DynaMAX 550P/560P/575P Waterjet Pump Operator Manual 811390 61
8. Empty the dirty water container, if necessary.
Redundant intensifiers
A second intensifier reduces downtime by permitting the operator to use one or the other. This
section describes how to change operation of the intensifiers on a pump with redundant units.
Change the intensifier that is in operation
Do this task when the pump is not operating.
1. Turn the primary breaker disconnect lever on the electrical enclosure door to OFF.
Refer to local regulations regarding waste water. Environmental rules can apply to
disposal.
Water in the container could have oil in it.
Intensifier 1 is the front unit, which is closest to the operator panel. Intensifier 2 is the rear unit.
Both intensifiers cannot run at the same time on this pump model.
4
2
5
1
3
1 Rear intensifier
2 Proximity switch
3 Top deck access holes
4 High-pressure water valve handle
5 Front intensifier