Preventive maintenance
DynaMAX 550P/560P/575P Waterjet Pump Operator Manual 811390 85
3. Remove a relief plug from the bottom of the motor.
4. Attach the grease gun coupler to the grease fitting on the same end of the motor as the open
relief plug.
5. Use the grease gun to put the specific quantity of grease in the motor.
6. Replace the grease cap.
7. Let the motor operate with the grease outlet open for 20 to 30 minutes.
8. Clean grease from the outside of the grease outlet and replace the relief plug.
9. Do this procedure again on the other end of the motor.
DynaMAX 550P DynaMAX 560P DynaMAX 575P
30 grams 40 grams 40 grams
CAUTION
It is possible that grease does not come out of the grease outlet when the
new grease is pumped in. Use only the recommended volume.
CAUTION
It is possible that grease does not come out of the grease outlet when the
new grease is pumped in. Use only the recommended volume.
CAUTION
It is possible that grease does not come out of the grease outlet when the
new grease is pumped in. Use only the recommended volume.