156 811390 Operator Manual DynaMAX 550P/560P/575P Waterjet Pump
Symptom Cause Solution
1 The fitting or the output
adapter is hot.
The high-pressure water fitting is
not installed correctly.
Make sure that some of the
threads on the high-pressure
tubing are visible at the fitting.
The high-pressure poppet is
leaking.
Disassemble the parts and
look for flaws, deterioration,
erosion marks, or cracks.
Make sure that the mating
surfaces are smooth and
clean.
If damage is found, replace
the component.
2 Water leaks from the output
adapter weep hole.
A high-pressure tubing
connection is loose or damaged.
Examine the connection.
Make sure that the fitting is
tightened correctly and to the
correct torque value.
The tube end is cracked or
damaged.
Replace the component.
The output adapter has failed.
42