EasyManuals Logo
Home>Hypertherm>Welding System>Powermax65 SYNC

Hypertherm Powermax65 SYNC Reference Guide

Hypertherm Powermax65 SYNC
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
Serial Communication Programmer Reference Guide
18 810400 Reference Guide Powermax65/85/105 SYNC
Request: Write operating settings and put the plasma power supply into remote control mode
0x3080 Operating mode setting N/A 10 (Write Multiple Registers) 0x2093
0x3081 Output current (A) setting Amperes 10 (Write Multiple Registers) 0x2094
0x3082 Gas pressure setting psi 10 (Write Multiple Registers) 0x2096
Request: Do a quick restart of the plasma power supply or clear fault code 0-50-0
0x308E Quick restart command
(Write a value of 0x0404 to this address.)
N/A 10 (Write Multiple Registers) N/A
0x308F Quick restart approval
(Write a value of 0x0618 to this address.)
N/A 10 (Write Multiple Registers) N/A
Request: Read the Start and Motion signal status of the plasma power supply
0x3100
(coil)
Start switch signal status
(ON = 1, OFF = 0)
N/A 01 (Read Coil) 0x0810
0x3101
(coil)
Motion switch signal status
(ON = 1, OFF = 0)
N/A 01 (Read Coil) 0x0811
Request: Start and stop a gas test
0x3180
(coil)
Gas test status
(Write a value of 0xFF00 to this coil to start a
gas test.)
(Write a value of 0x0000 to this coil to stop a
gas test.)
N/A 05 (Write Single Coil) 0x0832
SYNC
Address
Description Unit
Recommended Modbus
Function (hex)
Old
Address

Table of Contents

Other manuals for Hypertherm Powermax65 SYNC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax65 SYNC and is the answer not in the manual?

Hypertherm Powermax65 SYNC Specifications

General IconGeneral
BrandHypertherm
ModelPowermax65 SYNC
CategoryWelding System
LanguageEnglish

Related product manuals