Serial Communication Programmer Reference Guide
Powermax65/85/105 SYNC Reference Guide 810400 67
Figure 7 CNC starts and stops a gas test
TO TURN GAS ON
COIL WRITE 0xFF00 TO 0x3180
TO TURN GAS OFF
COIL WRITE 0x0000 TO 0x3180
READ ACTUAL PRESSURE.
REGISTER READ 0x3019
SET PRESSURE.
REGISTER WRITE 0x3082
OPTIONAL
EXIT
ENTER
TO TURN GAS ON
COIL WRITE 0xFF00 TO 0x0832
TO TURN GAS OFF
COIL WRITE 0x0000 TO 0x0832
READ ACTUAL PRESSURE.
REGISTER READ 0x204C
SET PRESSURE.
REGISTER WRITE 0x2096
ENTER
OPTIONAL
EXIT
DISPLAY ACTUAL
PRESSURE TO USER
SYNC
OLDER
DISPLAY ACTUAL
PRESSURE TO USER