EasyManuals Logo

Hypertherm Powermax65 SYNC Reference Guide

Hypertherm Powermax65 SYNC
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #72 background imageLoading...
Page #72 background image
Serial Communication Programmer Reference Guide
72 810400 Reference Guide Powermax65/85/105 SYNC
Figure 12 SYNC faults that clear with the next Start signal
ENTER
0-30-0 TSO OR 0-30-1 TSC
ELECTRODE-TO-NOZZLE
CONTINUITY FAULT.
PLASMA START IS
ALLOWED.
ARC CONTINUES. BUT
CARTRIDGE LIFE AND CUT
QUALITY MAY BE COMPROMISED.
0-12-1 OUTPUT GAS
PRESSURE LOW.
0-20-0 INLET AIR
PRESSURE IS TOO
LOW TO OPERATE.
PLASMA START NOT
ALLOWED UNTIL
PRESSURE IS RESTORED.
0-22-0
NO GAS INPUT.
0-32-0 CARTRIDGE IS
AT END OF LIFE.
SUGGEST REPLACING THE
CARTRIDGE IMMEDIATELY.
IF FAULT REPEATS OFTEN,
REPLACE THE CARTRIDGE.
DO A GAS TEST TO MAKE
SURE PRESSURE IS WITHIN
THE RANGE SPECIFIED.
FAULT CLEARS AUTOMATICALLY AT NEXT START.
0-32-1 CARTRIDGE
INSTALLED WAS
AT END OF LIFE
BEFORE NOW.
PLASMA START IS ALLOWED
BUT NOT RECOMMENDED.
CUT QUALITY MAY BE
COMPROMISED.
SYNC
USER INSTALLS A
NEW CARTRIDGE.

Table of Contents

Other manuals for Hypertherm Powermax65 SYNC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax65 SYNC and is the answer not in the manual?

Hypertherm Powermax65 SYNC Specifications

General IconGeneral
BrandHypertherm
ModelPowermax65 SYNC
CategoryWelding System
LanguageEnglish

Related product manuals