Serial Communication Programmer Reference Guide
72 810400 Reference Guide Powermax65/85/105 SYNC
Figure 12 SYNC faults that clear with the next Start signal
ENTER
0-30-0 TSO OR 0-30-1 TSC
ELECTRODE-TO-NOZZLE
CONTINUITY FAULT.
PLASMA START IS
ALLOWED.
ARC CONTINUES. BUT
CARTRIDGE LIFE AND CUT
QUALITY MAY BE COMPROMISED.
0-12-1 OUTPUT GAS
PRESSURE LOW.
0-20-0 INLET AIR
PRESSURE IS TOO
LOW TO OPERATE.
PLASMA START NOT
ALLOWED UNTIL
PRESSURE IS RESTORED.
0-22-0
NO GAS INPUT.
0-32-0 CARTRIDGE IS
AT END OF LIFE.
SUGGEST REPLACING THE
CARTRIDGE IMMEDIATELY.
IF FAULT REPEATS OFTEN,
REPLACE THE CARTRIDGE.
DO A GAS TEST TO MAKE
SURE PRESSURE IS WITHIN
THE RANGE SPECIFIED.
FAULT CLEARS AUTOMATICALLY AT NEXT START.
0-32-1 CARTRIDGE
INSTALLED WAS
AT END OF LIFE
BEFORE NOW.
PLASMA START IS ALLOWED
BUT NOT RECOMMENDED.
CUT QUALITY MAY BE
COMPROMISED.
SYNC
USER INSTALLS A
NEW CARTRIDGE.