3.
Record
that,
for
this
Linux
partition,
you
performed
substep
3
of
“Step
1321-24”
on
page
83
for
later
steps.
Use
the
following
command
to
list
diagela
messages
recorded
in
the
Linux
system
log:
cat
/var/log/platform
|grep
diagela
|more
Linux
run-time
diagela
error
messages
are
logged
in
the
platform
file
under
/var/log.
The
following
is
an
example
of
the
Linux
system
error
log
diagela
messages.
Aug
13
09:38:45
larry
diagela:
08/13/2003
09:38:44
Aug
13
09:38:45
larry
diagela:
Automatic
Error
Log
Analysis
has
detected
a
problem.
Aug
13
09:38:45
larry
diagela:
Aug
13
09:38:45
larry
diagela:
The
Service
Request
Number(s)/Probable
Cause(s)
Aug
13
09:38:45
larry
diagela:
(causes
are
listed
in
descending
order
of
probability):
Aug
13
09:38:45
larry
diagela:
Aug
13
09:38:45
larry
diagela:
651-880:
The
CEC
or
SPCN
reported
an
error.
Report
the
SRN
and
the
following
reference
and
physical
location
codes
to
your
service
provider.
Aug
13
09:38:45
larry
diagela:
Location:
n/a
FRU:
n/a
Ref-Code:
B1004699
Aug
13
09:38:45
larry
diagela:
Aug
13
09:38:45
larry
diagela:
Analysis
of
Error
log
sequence
number:
3
Aug
29
07:13:04
larry
diagela:
08/29/2003
07:13:04
Aug
29
07:13:04
larry
diagela:
Automatic
Error
Log
Analysis
has
detected
a
problem.
Aug
29
07:13:04
larry
diagela:
Aug
29
07:13:04
larry
diagela:
The
Service
Request
Number(s)/Probable
Cause(s)
Aug
29
07:13:04
larry
diagela:
(causes
are
listed
in
descending
order
of
probability):
Aug
29
07:13:04
larry
diagela:
Aug
29
07:13:04
larry
diagela:
651-880:
The
CEC
or
SPCN
reported
an
error.
Report
the
SRN
and
the
following
reference
and
physical
location
codes
to
your
service
provider.
Aug
29
07:13:04
larry
diagela:
Location:
U0.1-F4
FRU:
09P5866
Ref-Code:
10117661
Aug
29
07:13:04
larry
diagela:
Aug
29
07:13:04
larry
diagela:
Analysis
of
/var/log/platform
sequence
number:
24
Sep
4
06:00:55
larry
diagela:
09/04/2003
06:00:55
Sep
4
06:00:55
larry
diagela:
Automatic
Error
Log
Analysis
reports
the
following:
Sep
4
06:00:55
larry
diagela:
Sep
4
06:00:55
larry
diagela:
651204
ANALYZING
SYSTEM
ERROR
LOG
Sep
4
06:00:55
larry
diagela:
A
loss
of
redundancy
on
input
power
was
detected.
Sep
4
06:00:55
larry
diagela:
Sep
4
06:00:55
larry
diagela:
Check
for
the
following:
Sep
4
06:00:55
larry
diagela:
1.
Loose
or
disconnected
power
source
connections.
Sep
4
06:00:55
larry
diagela:
2.
Loss
of
the
power
source.
Sep
4
06:00:55
larry
diagela:
3.
For
multiple
enclosure
systems,
loose
or
Sep
4
06:00:55
larry
diagela:
disconnected
power
and/or
signal
connections
Sep
4
06:00:55
larry
diagela:
between
enclosures.
Sep
4
06:00:55
larry
diagela:
Sep
4
06:00:55
larry
diagela:
Supporting
data:
Sep
4
06:00:55
larry
diagela:
Ref.
Code:
10111520
Sep
4
06:00:55
larry
diagela:
Location
Codes:
P1
P2
Sep
4
06:00:55
larry
diagela:
Sep
4
06:00:55
larry
diagela:
Analysis
of
/var/log/platform
sequence
number:
13
84