MAP
154B:
Insufficient
Hardware
Resources
Problem
Isolation
Step
154B-1
Record
the
error
code,
location
code(s)
and
word
13
that
sent
you
to
this
MAP.
Step
154B-2
Turn
off
the
power.
Step
154B-3
Make
sure
the
power
is
off
on
the
base
system
drawer.
Step
154B-4
Attention:
Before
replacing
any
parts
examine
the
base
system
drawer
for
violation
of
any
of
the
following
configuration
constraints.
v
Memory
DIMMs
must
be
installed
in
quads
and
in
the
correct
slots.
A
quad
is
a
group
of
four
memory
DIMMs.
v
Quads
are
populated
in
DIMM
slots
1,
3,
6,
8
first,
and
then
2,
4,
5,
7.
The
only
two
valid
slot
combinations
that
you
can
use
are
1,
3,
6,
and
8
OR
2,
4,
5,
and
7.
v
At
least
one
quad
of
DIMMs
must
be
installed
on
the
system
backplane:
U0.1-P1-My,
where
y
is
1,
3,
6,
and
8.
See
the
illustration
in
“Memory
DIMM
Locations”
on
page
17.
v
Each
memory
DIMM
in
a
quad
must
be
the
same
type
and
size.
However,
both
quads
on
the
system
backplane
are
not
required
to
be
the
same.
Replace
the
following
cards,
if
present,
one
at
a
time:
v
First
location
code
item
recorded,
if
any,
in
“Step
154B-1.”
v
Second
location
code
item
recorded,
if
any,
in
“Step
154B-1.”
v
Third
location
code
item
recorded,
if
any,
in
“Step
154B-1.”
v
Replace
the
service
processor
card
at
U0.1-P1-X1,
if
not
recorded
in
“Step
154B-1.”
v
If
the
value
of
word
13,
recorded
in
“Step
154B-1,”
is
402F0000,
403F0000,
or
40FF0000,
replace
the
processor
backplane
at
U0.1-P1,
if
not
recorded
in“Step
154B-1.”
v
If
the
value
of
word
13,
recorded
in
“Step
154B-1,”
is
40600000,
replace
the
system
backplane
at
U0.1-P1,
if
not
recorded
in
“Step
154B-1.”
v
If
the
value
of
word
13,
recorded
in
“Step
154B-1,”
is
41100000,
replace
the
system
backplane
at
U0.1-P1,
if
not
recorded
in
“Step
154B-1.”
v
Memory
DIMMs
at
locations
U0.1-P1-M1,
M3,
M6,
M8,
if
not
recorded
in
“Step
154B-1.”
v
Memory
DIMMs
at
locations
U0.1-P1-M2,
M4,
M5,
M7,
if
not
recorded
in
“Step
154B-1.”
v
System
backplane
at
U0.1-P1,
if
not
recorded
in
“Step
154B-1”
and
if
not
already
replaced.
Step
154B-5
Turn
on
the
power.
Step
154B-6
Did
the
system
stop
with
the
same
error
code
as
recorded
in
“Step
154B-1”?
No
The
card
just
replaced
was
defective.
This
ends
the
procedure.
Go
to
MAP
0410:
Repair
Checkout
in
the
RS/6000
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems.
Yes
Go
to
“Step
154B-7.”
Step
154B-7
Have
all
the
cards
listed
in
“Step
154B-4”
been
replaced?
No
Go
to
“Step
154B-2.”
128
EserverpSeries