Page #372 background image
10.
Return
the
system
to
the
operating
position
as
described
in
“Returning
the
Model
6C3
to
the
Operating
Position”
on
page
285
or
“Placing
the
Model
6E3
into
the
Service
and
Operating
Position”
on
page
286.
11.
Start
the
system
as
described
in
“Starting
the
System”
on
page
283.
Installing
or
Replacing
a
Power
Supply
with
the
System
Power
On
The
system
power
can
remain
on
when
a
second
power
supply
installed
or
when
one
of
the
two
power
supplies
present
in
the
system
is
replaced.
To
install
a
second
power
supply,
or
to
replace
a
failing
power
supply
when
two
are
present
in
the
system,
do
the
following:
1.
On
a
Model
6C3,
open
the
rear
rack
door.
2.
If
a
failing
power
supply
is
present,
disconnect
the
power
cable
from
the
failing
power
supply
at
the
rear
of
the
system.
3.
Place
the
system
into
the
service
position
as
described
in
“Placing
the
Model
6C3
into
the
Service
Position”
on
page
284
or
“Placing
the
Model
6E3
into
the
Service
and
Operating
Position”
on
page
286.
4.
Remove
the
service
access
cover
as
described
in
“Removing
the
Model
6C3
Service
Access
Cover”
on
page
288
or
“Removing
the
Model
6E3
Service
Access
Cover”
on
page
289.
5.
Ensure
the
power
supply
bay
is
empty
by
doing
one
of
the
following:
a.
Remove
the
power
supply
filler
by
grasping
the
handle
and
pulling
the
filler
inward
and
then
up
and
out
of
the
system.
b.
Remove
a
failing
power
supply
by
doing
the
following:
1)
Grasp
the
ends
of
the
power
supply
handles,
and
press
the
retractable
spring-activated
portion
of
each
handle.
This
action
releases
the
spring
latch
located
on
the
bottom
side
of
each
handle.
See
the
following
illustration.
2)
Lift
the
power
supply
release
handles
until
they
are
perpendicular
(90
degrees)
to
the
top
of
the
power
supply.
By
placing
the
handles
perpendicular
to
the
top
of
the
power
supply,
the
base
or
hinged
portion
of
each
handle
acts
as
a
cam
and
helps
pry
the
power
supply
from
its
connector
located
on
the
system
backplane.
3)
After
the
power
supply
is
released
from
its
connector,
pull
the
power
supply
straight
out
from
the
system.
6.
Grasp
the
power
supply
handles
located
on
top
of
the
new
power
supply.
Pivot
the
power
supply
handles
upward
to
90
degrees.
This
action
puts
the
handle
cams
into
the
correct
position
to
help
seat
the
power
supply
into
its
connector.
7.
Carefully
insert
the
new
power
supply
into
the
power
supply
bay.
352
EserverpSeries
615
Service
Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM P 615 series and is the answer not in the manual?

IBM P 615 series Specifications

General IconGeneral
BrandIBM
ModelP 615 series
CategoryServer
LanguageEnglish

Related product manuals