EasyManua.ls Logo

IBM P 615 series

IBM P 615 series
491 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operator
Panel
Error
Codes
Attention:
If
you
replace
FRUs
or
perform
an
action
and
the
problem
is
still
not
corrected,
go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110
unless
otherwise
indicated
in
the
tables.
If
you
replace
FRUs
and
the
problem
is
corrected,
go
to
MAP
0410:
Repair
Checkout
in
the
RS/6000
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems.
Table
3.
Operator
Panel
Error
Codes.
Error
Code
Description
Action/
Possible
Failing
FRU
0000
1111
At
power
on,
failure
of
power-good
signal
from
power
supply.
1.
CEC
backplane
Location:
U0.1-P1
2.
CEC
backplane
power
supply
Locations:
U0.1-V1
U0.1-V2
0000
1112
At
power
off,
failure
of
power-good
signal
from
power
supply.
1.
CEC
backplane
Location:
U0.1-P1
2.
CEC
backplane
power
supply
Locations:
U0.1-V1
U0.1-V2
0000
1113
While
power
on,
failure
of
power-good
signal
from
power
supply.
1.
CEC
backplane
Location:
U0.1-P1
2.
CEC
backplane
power
supply
Locations:
U0.1-V1
U0.1-V2
0000
1114
Operator
panel
and
service
processor
have
been
reset
after
main
power
disturbance.
Informational
message
0000
2222
Operator
panel
not
communicating
with
service
processor
1.
If
system
cannot
be
powered
off,
reset
the
service
processor
(via
the
pinhole
reset
or
by
disconnecting
then
reconnecting
power).
2.
CEC
backplane
Location:
U0.1-P1
0000
3333
SPCN
communications
error
CEC
backplane
Location:
U0.1-P1
0000
3334
I2C
repeater
error
CEC
backplane
Location:
UO.1-P1
0000
BBBB
TOD
battery
malfunction
TOD
battery
Location:
U0.1-P1-V3
166
EserverpSeries
615
Service
Guide

Table of Contents